Parametry falownika Danfoss VLT MicroDrive FC51
0-** Operation/Display | 6-13 Terminal 53 High Current |
0-0* Basic Settings | 0.01-20.00 mA *20.00 mA |
0-03 Regional Settings | 6-14 Term. 53 Low Ref./Feedb. |
*[0] International | Value |
[1] US | -4999-4999 *0.000 |
0-04 Oper. State at Power-up | 6-15 Term. 53 High Ref./Feedb. |
(Hand) | Value |
[0] Resume | -4999-4999 *50.000 |
*[1] Forced stop, ref=old | 6-16 Terminal 53 Filter Time |
[2] Forced stop, ref=0 | Constant |
0-1* Set-up Handling | 0.01-10.00 s *0.01 s |
0-10 Active Set-up | 6-19 Terminal 53 mode |
*[1] Setup 1 | *[0] Voltage mode |
[2] Setup 2 | [1] Current mode |
[9] Multi Setup | 6-2* Analog Input 2 |
0-11 Edit Set-up | 6-22 Terminal 60 Low Current |
*[1] Setup 1 | 0.00-19.99 mA *0.14 mA |
[2] Setup 2 | 6-23 Terminal 60 High Current |
[9] Active Setup | 0.01-20.00 mA *20.00 mA |
0-12 Link Setups | 6-24 Term. 60 Low Ref./Feedb. |
[0] Not Linked | Value |
*[20] Linked | -4999-4999 *0.000 |
0-31 Custom Readout Min Scale | 6-25 Term. 60 High Ref./Feedb. |
0.00 - 9999.00 * 0.00 | Value |
0-32 Custom Readout Max Scale | -4999-4999 *50.00 |
0.00 - 9999.00 * 100.0 | 6-26 Terminal 60 Filter Time |
0-4* LCP Keypad | Constant |
0-40 [Hand on] Key on LCP | 0.01-10.00 s *0.01 s |
[0] Disabled | 6-8* LCP Potentiometer |
*[1] Enabled | 6-80 LCP Potmeter Enable |
0-41 [Off / Reset] Key on LCP | [0] Disabled |
[0] Disable All | *[1] Enable |
*[1] Enable All | 6-81 LCP potm. Low Reference |
[2] Enable Reset Only | -4999-4999 *0.000 |
0-42 [Auto on] Key on LCP | 6-82 LCP potm. High Reference |
[0] Disabled | -4999-4999 *50.00 |
*[1] Enabled | 6-9* Analog Output xx |
0-5* Copy/Save | 6-90 Terminal 42 Mode |
0-50 LCP Copy | *[0] 0-20 mA |
*[0] No copy | [1] 4-20 mA |
[1] All to LCP | [2] Digital Output |
[2] All from LCP | 6-91 Terminal 42 Analog Output |
[3] Size indep. from LCP | *[0] No operation |
0-51 Set-up Copy | [10] Output Frequency |
*[0] No copy | [11] Reference |
[1] Copy from setup 1 | [12] Feedback |
[2] Copy from setup 2 | [13] Motor Current |
[9] Copy from Factory setup | [16] Power |
0-6* Password | [19] DC Link Voltage |
0-60 (Main) Menu Password | [20] Bus Reference |
0-999 *0 | 6-92 Terminal 42 Digital Output |
0-61 Access to Main/Quick Menu | Patrz par. 5-40 |
w/o Password | *[0] No Operation |
*[0] Full access | [80] SL Digital Output A |
[1] LCP:Read Only | 6-93 Terminal 42 Output Min |
[2] LCP:No Access | Scale |
1-** Load/Motor | 0.00-200.0% *0.00% |
1-0* General Settings | 6-94 Terminal 42 Output Max |
1-00 Configuration Mode | Scale |
*[0] Speed open loop | 0.00-200.0% *100.0% |
[3] Process | 7-** Controllers |
1-01 Motor Control Principle | 7-2* Process Ctrl. Feedb |
[0] U/f | 7-20 Process CL Feedback 1 |
*[1] VVCplus | Resource |
1-03 Torque Characteristics | *[0] NoFunction |
*[0] Constant torque | [1] Analog Input 53 |
[2] Automatic Energy Optim. | [2] Analog input 60 |
1-05 Local Mode Configuration | [8] PulseInput33 |
[0] Speed Open Loop | [11] LocalBusRef |
*[2] Jak konfiguracja w par. 1-00 | 7-3* Process PI |
1-2* Motor Data | Ctrl. 7-30 Process PI Normal/ |
1-20 Motor Power [kW] [HP] | Inverse Ctrl |
[1] 0,09 kW/0,12 KM | *[0] Normal |
[2] 0,12 kW/0,16 KM | [1] Inverse |
[3] 0,18 kW/0,25 KM | 7-31 Process PI Anti Windup |
[4] 0,25 kW/0,33 KM | [0] Disable |
[5] 0,37 kW/0,50 KM | *[1] Enable |
[6] 0,55 kW/0,75 KM | 7-32 Process PI Start Speed |
[7] 0,75 kW/1,00 KM | 0.0-200.0 Hz *0.0 Hz |
[8] 1,10 kW/1,50 KM | 7-33 Process PI Proportional Gain |
[9] 1,50 kW/2,00 KM | 0.00-10.00 *0.01 |
[10] 2,20 kW/3,00 KM | 7-34 Process PI Integral Time |
[11] 3,00 kW/4,00 KM | 0.10-9999 s *9999 s |
[12] 3,70 kW/5,00 KM | 7-38 Process PI Feed Forward |
[13] 4,00 kW/5,40 KM | Factor |
[14] 5,50 kW/7,50 KM | 0-400% *0% |
[15] 7,50 kW/10,00 KM | 7-39 On Reference Bandwidth |
[16] 11,00 kW/15,00 KM | 0-200% *5% |
[17] 15,00 kW/20,00 KM | 8-** Comm. and Options |
[18] 18,50 kW/25,00 KM | 8-0* General Settings |
[19] 22,00 kW/29,50 KM | 8-01 Control Site |
[20] 30,00 kW/40,00 KM | *[0] Digital and ControlWord |
1-22 Motor Voltage | [1] Digital only |
50-999 V *230 -400 V | [2] ControlWord only |
1-23 Motor Frequency | 8-02 Control Word Source |
20-400 Hz *50 Hz | [0] None |
1-24 Motor Current | *[1] FC RS485 |
0.01-100.00 A *Zależnie od silnika | 8-03 Control Word Timeout Time |
1-25 Motor Nominal Speed | 0.1-6500 s *1.0 s |
100-9999 rpm *Zależnie od typu | 8-04 Control Word Timeout |
silnika | Function |
1-29 Automatic Motor Tuning | *[0] Off |
(AMT) | [1] Freeze Output |
*[0] Off | [2] Stop |
[2] Enable AMT | [3] Jog |
[3] Complete AMT with Rotating | [4] Max. Speed |
motor | [5] Stop and trip |
1-3* Adv. Motor Data | 8-06 Reset Control Word Timeout |
1-30 Stator Resistance (Rs) | *[0] No Function |
[Ohm] * Zależnie od danych silnika | [1] Do reset |
1-33 Stator Leakage Reactance | 8-3* FC Port Settings |
(X1) | 8-30 Protocol |
[Ohm] * Zależnie od danych silnika | *[0] FC |
1-35 Main Reactance (Xh) | [2] Modbus |
[Ohm] * Zależnie od danych silnika | 8-31 Address |
1-5* Load Indep. Setting | 1-247 *1 |
1-50 Motor Magnetisation at 0 | 8-32 FC Port Baud Rate |
Speed | [0] 2400 Baud |
0-300% *100% | [1] 4800 Baud |
1-52 Min Speed Norm. Magnet. | *[2] 9600 Baud (aby wybrać |
[Hz] | magistralę FC w 8-30) |
0.0-10.0 Hz *0.0Hz | *[3] 19200 Baud (aby wybrać |
1-55 U/f Characteristic - U | magistralę Modbus w 8-30) |
0-999.9 V | [4] 38400 bodów |
1-56 U/f Characteristic - F | 8-33 FC Port Parity |
0-400 Hz | *[0] Even Parity, 1 Stop Bit |
1-6* Load Depen. Setting | [1] Odd Parity, 1 Stop Bit |
1-60 Low Speed Load Compen- | [2] No Parity, 1 Stop Bit |
sation | [3] No Parity, 2 Stop Bits |
0-199% *100% | 8-35 Minimum Response Delay |
1-61 High Speed Load Compen- | 0.001-0.5 *0.010 s |
sation | 8-36 Max Response Delay |
0-199% *100% | 0.100-10.00 s *5.000 s |
1-62 Slip Compensation | 8-4* FC MC protocol set |
-400-399% *100% | 8-43 FC Port PCD Read Configu- |
1-63 Slip Compensation Time | ration |
Constant | *[0] None Expressionlimit |
0.05-5.00 s *0.10 s | [1] [1500] Operation Hours |
1-7* Start Adjustments | [2] [1501] Running Hours |
1-71 Start Delay | [3] [1502] kWh Counter |
0.0-10.0 s *0.0 s | [4] [1600] Control Word |
1-72 Start Function | [5] [1601] Reference [Unit] |
[0] DC hold/delay time | [6] [1602] Reference % |
[1] DC brake/delay time | [7] [1603] Status Word |
*[2] Coast/delay time | [8] [1605] Main Actual Value [%] |
1-73 Flying Start | [9] [1609] Custom Readout |
*[0] Disabled | [10] [1610] Power [kW] |
[1] Enabled | [11] [1611] Power [hp] |
1-8* Stop Adjustments | [12] [1612] Motor Voltage |
1-80 Function at Stop | [13] [1613] Frequency |
*[0] Coast | [14] [1614] Motor Current |
[1] DC hold | [15] [1615] Frequency [%] |
1-82 Min Speed for Funct. at Stop | [16] [1618] Motor Thermal |
[Hz] | [17] [1630] DC Link Voltage |
0.0-20.0 Hz *0.0 Hz | [18] [1634] Heatsink Temp. |
1-9*Motor Temperature | [19] [1635] Inverter Thermal |
1-90 Motor Thermal Protection | [20] [1638] SL Controller State |
*[0] No protection | [21] [1650] External Reference |
[1] Termistor warning | [22] [1651] Pulse Reference |
[2] Thermistor trip | [23] [1652] Feedback [Unit] |
[3] Etr warning | [24] [1660] Digital Input 18,19,27,33 |
[4] Etr trip | [25] [1661] Digtial Input 29 |
1-93 Thermistor Resource | [26] [1662] Analog Input 53 (V) |
*[0] None | [27] [1663] Analog Input 53 (mA) |
[1] Analog input 53 | [28] [1664] Analog Input 60 |
[6] Digital input 29 | [29] [1665] Analog Output 42 [mA] |
2-** Brakes | [30] [1668] Freq. Input 33 [Hz] |
2-0* DC-Brake | [31] [1671] Relay Output [bin] |
2-00 DC Hold Current | [32] [1672] Counter A |
0-150% *50% | [33] [1673] Counter B |
2-01 DC Brake Current | [34] [1690] Alarm Word |
0-150% *50% | [35] [1692] Warning Word |
2-02 DC Braking Time | [36] [1694] Ext. Status Word |
0.0-60.0 s *10.0s | 8-5* Digital/Bus |
2-04 DC Brake Cut In Speed | 8-50 Coasting Select |
0.0-400.0 Hz *0.0Hz | [0] DigitalInput |
2-1* Brake Energy Funct. | [1] Bus |
2-10 Brake Function | [2] LogicAnd |
*[0] Off | *[3] LogicOr |
[1] Resistor brake | 8-51 Quick Stop Select |
[2] AC brake | Patrz par. 8-50 * [3] LogicOr |
2-11 Brake Resistor (ohm) | 8-52 DC Brake Select |
Min./maks./domyślnie: Zależnie od | Patrz par. 8-50 *[3] LogicOr |
wielkości mocy. | 8-53 Start Select |
2-14 Brake Voltage reduce | Patrz par. 8-50 *[3] LogicOr |
0 - Zależnie od wielkości mocy.* 0 | 8-54 Reversing Select |
2-16 AC Brake, Max current | Patrz par. 8-50 *[3] LogicOr |
0-150% *100% | 8-55 Set-up Select |
2-17 Overvoltage Control | Patrz par. 8-50 *[3] LogicOr |
*[0] Disabled | 8-56 Preset Reference Select |
[1] Enabled (not at stop) | Patrz par. 8-50 * [3] LogicOr |
[2] Enabled | 8-8* Bus communication |
2-2* Mechanical Brake | Diagnostics |
2-20 Release Brake Current | 8-80 Bus Message Count |
0.00-100.0 A *0.00 A | 0-0 N/A *0 N/A |
2-22 Activate Brake Speed [Hz] | 8-81 Bus Error Count |
0.0-400.0 Hz *0.0 Hz | 0-0 N/A *0 N/A |
3-** Reference / Ramps | 8-82 Slave Messages Rcvd |
3-0* Reference Limits | 0-0 N/A *0 N/A |
3-00 Reference Range | 8-83 Slave Error Count |
*[0] Min - Max | 0-0 N/A *0 N/A |
[1] -Max - +Max | 8-9* Bus Jog / Feedback |
3-02 Minimum Reference | 8-94 Bus feedback 1 |
-4999-4999 *0.000 | 0x8000-0x7FFF *0 |
3-03 Maximum Reference | 13-** Smart Logic |
-4999-4999 *50.00 | 13-0* SLC Settings |
3-1* References | 13-00 SL Controller Mode |
3-10 Preset Reference | *[0] Off |
-100.0-100.0% *0.00% | [1] On |
3-11 Jog Speed [Hz] | 13-01 Start Event |
0.0-400.0 Hz *5.0 Hz | [0] False |
3-12 Catch up/slow Down Value | [1] True |
0.00 - 100.0% * 0.00% | [2] Running |
3-14 Preset Relative Reference | [3] InRange |
-100.0-100.0% *0.00% | [4] OnReference |
3-15 Reference Resource 1 | [7] OutOfCurrentRange |
[0] No function | [8] BelowILow |
*[1] Analog Input 53 | [9] AboveIHigh |
[2] Analog input 60 | [16] ThermalWarning |
[8] Pulse input 33 | [17] MainOutOfRange |
[11] Local bus ref | [18] Reversing |
[21] LCP Potentiometer | [19] Warning |
3-16 Reference Resource 2 | [20] Alarm_Trip |
[0] No function | [21] Alarm_TripLock |
[1] Analog in 53 | [22-25] Comparator 0-3 |
*[2] Analog in 60 | [26-29] LogicRule0-3 |
[8] Pulse input 33 | [33] DigitalInput_18 |
*[11] Local bus reference | [34] DigitalInput_19 |
[21] LCP Potentiometer | [35] DigitalInput_27 |
3-17 Reference Resource 3 | [36] DigitalInput_29 |
[0] No function | [38] DigitalInput_33 |
[1] Analog Input 53 | *[39] StartCommand |
[2] Analog input 60 | [40] DriveStopped |
[8] Pulse input 33 | 13-02 Stop Event |
*[11] Local bus ref | Patrz par. 13-01 * [40] DriveS- |
[21] LCP Potentiometer | topped |
3-18 Relative Scaling Ref. | 13-03 Reset SLC |
Resource | *[0] Do not reset |
*[0] No function | [1] Reset SLC |
[1] Analog Input 53 | 13-1* Comparators |
[2] Analog input 60 | 13-10 Comparator Operand |
[8] Pulse input 33 | *[0] Disabled |
[11] Local bus ref | [1] Reference |
[21] LCP Potentiometer | [2] Feedback |
3-4* Ramp 1 | [3] MotorSpeed |
3-40 Ramp 1 Type | [4] MotorCurrent |
*[0] Linear | [6] MotorPower |
[2] Sine2 ramp | [7] MotorVoltage |
3-41 Ramp 1 Ramp up Time | [8] DCLinkVoltage |
0.05-3600 s *3.00 s (10.00 s1)) | [12] AnalogInput53 |
3-42 Ramp 1 Ramp Down Time | [13] AnalogInput60 |
0.05-3600 s *3.00s (10.00s 1)) | [18] PulseInput33 |
3-5* Ramp 2 | [20] AlarmNumber |
3-50 Ramp 2 Type | [30] CounterA |
*[0] Linear | [31] CounterB |
[2] Sine2 ramp | 13-11 Comparator Operator |
3-51 Ramp 2 Ramp up Time | [0] Less Than |
0.05-3600 s *3.00 s (10.00 s 1)) | *[1] Approximately equals |
3-52 Ramp 2 Ramp down Time | [2] Greater Than |
0.05-3600 s *3.00 s (10.00 s1)) | 13-12 Comparator Value |
3-8* Other Ramps | -9999-9999 *0.0 |
3-80 Jog Ramp Time | 13-2* Timers |
0.05-3600 s *3.00 s (10.00s1)) | 13-20 SL Controller Timer |
3-81 Quick Stop Ramp Time | 0.0-3600 s *0.0 s |
0.05-3600 s *3.00 s (10.00s1)) | 13-4* Logic Rules |
4-** Limits/Warnings | 13-40 Logic Rule Boolean 1 |
4-1* Motor Limits | Patrz par. 13-01 *[0] False |
4-10 Motor Speed Direction | [30] - [32] Time-out SL 0-2 |
*[0] W prawo, jeśli parametr 1-00 | 13-41 Logic Rule Operator 1 |
ustawiono na sterowanie w pętli | *[0] Disabled |
zamkniętej | [1] And |
[1] W lewo | [2] Or |
*[2] Oba kierunki, jeśli par. 1-00 | [3] And not |
ustawiono na sterowanie w pętli | [4] Or not |
otwartej | [5] Not and |
4-12 Motor Speed Low Limit [Hz] | [6] Not or |
0.0-400.0 Hz *0.0 Hz | [7] Not and not |
4-14 Motor Speed High Limit [Hz] | [8] Not or not |
0.1-400.0 Hz *65.0 Hz | 13-42 Logic Rule Boolean 2 |
4-16 Torque Limit Motor Mode | Patrz par. 13-40 * [0] False |
0-400% *150% | 13-43 Logic Rule Operator 2 |
4-17 Torque Limit Generator | Patrz par. 13-41 *[0] Disabled |
Mode | 13-44 Logic Rule Boolean 3 |
0-400% *100% | Patrz par. 13-40 * [0] False |
4-4* Adj. Warnings 2 | 13-5* States |
4-40 Warning Frequency Low | 13-51 SL Controller Event |
0.00 - Wartość 4-41 Hz *0.0 Hz | Patrz par. 13-40 *[0] False |
4-41 Warning Frequency High | 13-52 SL Controller Action |
Wartość 4-40-400.0 Hz *400.00 Hz | *[0] Disabled |
4-5* Adj. Warnings | [1] NoAction |
4-50 Warning Current Low | [2] SelectSetup1 |
0.00-100.00 A *0.00 A | [3] SelectSetup2 |
4-51 Warning Current High | [10-17] SelectPresetRef0-7 |
0.0-100.00 A *100.00 A | [18] SelectRamp1 |
4-54 Warning Reference Low | [19] SelectRamp2 |
-4999.000 - Wartość 4-55 | [22] Run |
* -4999.000 | [23] RunReverse |
4-55 Warning Reference High | [24] Stop |
Wartość 4-54 -4999.000 | [25] Qstop |
*4999.000 | [26] DCstop |
4-56 Warning Feedback Low | [27] Coast |
-4999.000 - Wartość 4-57 | [28] FreezeOutput |
* -4999.000 | [29] StartTimer0 |
4-57 Warning Feedback High | [30] StartTimer1 |
Wartość 4-56-4999.000 *4999.000 | [31] StartTimer2 |
4-58 Missing Motor Phase | [32] Set Digital Output A Low |
Function | [33] Set Digital Output B Low |
[0] Off | [38] Set Digital Output A High |
*[1] On | [39] Set Digital Output B High |
4-6* Speed Bypass | [60] ResetCounterA |
4-61 Bypass Speed From [Hz] | [61] ResetCounterB |
0.0-400.0 Hz *0.0 Hz | 14-** Special Functions |
4-63 Bypass Speed To [Hz] | 14-0* Inverter Switching |
0.0 -400.0 Hz *0.0 Hz | 14-01 Switching Frequency |
5-1* Digital Inputs | [0] 2 kHz |
5-10 Terminal 18 Digital Input | *[1] 4 kHz |
[0] No function | [2] 8 kHz |
[1] Reset | [4] 16 kHz (niedostępne dla M5) |
[2] Coast inverse | 14-03 Overmodulation |
[3] Coast and reset inv. | [0] Off |
[4] Quick stop inverse | *[1] On |
[5] DC-brake inv. | 14-1* Mains monitoring |
[6] Stop inv | 14-12 Function at mains |
*[8] Start | imbalance |
[9] Latched start | *[0] Trip |
[10] Reversing | [1] Warning |
[11] Start reversing | [2] Disabled |
[12] Enable start forward | 14-2* Trip Reset |
[13] Enable start reverse | 14-20 Reset Mode |
[14] Jog | *[0] Manual reset |
[16-18] Preset ref bit 0-2 | [1-9] AutoReset 1-9 |
[19] Freeze reference | [10] AutoReset 10 |
5-10 Terminal 18 Digital Input | [11] AutoReset 15 |
[20] Freeze output | [12] AutoReset 20 |
[21] Speed up | [13] Infinite auto reset |
[22] Speed down | [14] Reset at power up |
[23] Setup select bit 0 | 14-21 Automatic Restart Time |
[28] Catch up | 0 - 600s * 10s |
[29] Slow down | 14-22 Operation Mode |
[34] Ramp bit 0 | *[0] Normal Operation |
[60] Counter A (up) | [2] Initialisation |
[61] Counter A (down) | 14-26 Action At Inverter Fault |
[62] Reset counter A | *[0] Trip |
[63] Counter B (up) | [1] Warning |
[64] Counter B (down) | 14-4* Energy Optimising |
[65] ResetCounter B | 14-41 AEO Minimum Magneti- |
5-11 Terminal 19 Digital Input | sation |
Patrz par. 5-10. * [10] Reversing | 40 - 75 % * 66 % |
5-12 Terminal 27 Digital Input | 14-9* Fault Settings |
Patrz par. 5-10. * [1] Reset | 14-90 Fault level[3] Trip Lock |
5-13 Terminal 29 Digital Input | [4] Trip with delayed reset |
Patrz par. 5-10. * [14] Jog | 15-** Drive Information |
5-15 Terminal 33 Digital Input | 15-0* Operating Data |
Patrz par. 5-10. * [16] Preset ref bit | 15-00 Operating Days |
0 | 15-01 Running Hours |
[26] Precise Stop Inverse | 15-02 kWh Counter |
[27] Start, Precise Stop | 15-03 Power Ups |
[32] Pulse Input | 15-04 Over Temps |
5-3* Digital Outputs | 15-05 Over Volts |
5-34 On Delay, Terminal 42 Digital | 15-06 Reset kWh Counter |
Output | *[0] Do not reset |
0.00 - 600.00 s * 0.01 s | [1] Reset counter |
5-35 Off Delay, Terminal 42 Digital | 15-07 Reset Running Hours |
Output | Counter |
0.00 - 600.00 s * 0.01 s | *[0] Do not reset |
5-4* Relays | [1] Reset counter |
5-40 Function Relay | 15-3* Fault Log |
*[0] No operation | 15-30 Fault Log: Error Code |
[1] Control ready | 15-4* Drive Identification |
[2] Drive ready | 15-40 FC Type |
[3] Drive ready, Remote | 15-41 Power Section |
[4] Enable / No warning | 15-42 Voltage |
[5] Drive running | 15-43 Software Version |
[6] Running / No warning | 15-46 Frequency Converter Order. |
[7] Run in range / No warning | No |
[8] Run on ref / No warning | 15-48 LCP Id No |
[9] Alarm | 15-51 Frequency Converter Serial |
[10] Alarm or warning | No |
[12] Out of current range | 16-** Data Readouts 16-0* General |
[13] Below current, low | Status |
[14] Above current, high | 16-00 Control Word |
[16] Below frequency, low | 0-0XFFFF |
[17] Above frequency, high | 16-01 Reference [Unit] |
[19] Below feedback, low | -4999-4999 *0.000 |
[20] Above feedback, high | 16-02 Reference % |
[21] Thermal warning | -200.0-200.0% *0.0% |
[22] Ready, No thermal warning | 16-03 Status Word |
[23] Remote ready, No thermal | 0-0XFFFF |
warning | 16-05 Main Actual Value [%] |
[24] Ready, Voltage ok | -200.0-200.0% *0.0% |
[25] Reverse | 16-09 Custom Readout |
[26] Bus ok | Zależnie od par. 0-31, 0-32 |
[28] Brake,NoWarn | 16-1* Motor Status |
[29] Brake ready/NoFault | 16-10 Power [kW] |
[30] BrakeFault (IGBT) | 16-11 Power [hp] |
[32] Mech.brake control | 16-12 Motor Voltage [V] |
[36] Control word bit 11 | 16-13 Frequency [Hz] |
[41] Below reference, low | 16-14 Motor Current [A] |
[42] Above reference, high | 16-15 Frequency [%] |
[51] Local ref. active | 16-18 Motor Thermal [%] |
5-40 Function Relay | 16-3* Drive Status |
[52] Remote ref. active | 16-30 DC Link Voltage |
[53] No alarm | 16-34 Heatsink Temp. |
[54] Start cmd active | 16-35 Inverter Thermal |
[55] Running reverse | 16-36 Inv.Nom. Current |
[56] Drive in hand mode | 16-37 Inv. Max. Current |
[57] Drive in auto mode | 16-38 SL Controller State |
[60-63] Comparator 0-3 | 16-5* Ref./Feedb. |
[70-73] Logic rule 0-3 | 16-50 External Reference |
[81] SL digital output B | 16-51 Pulse Reference |
5-41 On Delay, Relay | 16-52 Feedback [Unit] |
0.00-600.00 s *0.01 s | 16-6* Inputs/Outputs |
5-42 Off Delay, Relay | 16-60 Digital Input 18,19,27,33 |
0.00-600.00 s *0.01 s | 0-1111 |
5-5* Pulse Input | 16-61 Digital Input 29 |
5-55 Terminal 33 Low Frequency | 0-1 |
20-4999 Hz *20 Hz | 16-62 Analog Input 53 (volt) |
5-56 Terminal 33 High Frequency | 16-63 Analog Input 53 (current) |
21-5000 Hz *5000 Hz | 16-64 Analog Input 60 |
5-57 Term. 33 Low Ref./Feedb. | 16-65 Analog Output 42 [mA] |
Value | 16-68 Pulse Input [Hz] |
-4999-4999 *0.000 | 16-71 Relay Output [bin] |
5-58 Term. 33 High Ref./Feedb. | 16-72 Counter A |
Value | 16-73 Counter B |
-4999-4999 *50.000 | 16-8* Fieldbus/FC Port |
6-** Analog In/Out | 16-86 FC Port REF 1 |
6-0* Analog I/O Mode | 0x8000-0x7FFFF |
6-00 Live Zero Timeout Time | 16-9* Diagnosis Readouts |
1-99 s *10 s | 16-90 Alarm Word |
6-01 Live Zero TimeoutFunction | 0-0XFFFFFFFF |
*[0] Off | 16-92 Warning Word |
[1] Freeze output | 0-0XFFFFFFFF |
[2] Stop | 16-94 Ext. Status Word |
[3] Jog | 0-0XFFFFFFFF |
[4] Max speed | 18-** Extended Motor Data |
[5] Stop and trip | 18-8* Motor Resistors |
6-1* Analog Input 1 | 18-80 Stator Resistance (High |
6-10 Terminal 53 Low Voltage | resolution) |
0.00-9.99 V *0.07 V | 0.000-99.990 ohm *0.000 ohm |
6-11 Terminal 53 High Voltage | 18-81 Stator Leakage |
0.01-10.00 V *10.00 V | Reactance(High resolution) |
6-12 Terminal 53 Low Current | 0.000-99.990 ohm *0.000 ohm |
0.00-19.99 mA *0.14 mA |
1) Tylko dla M4 i M5